When the temperature drops below freezing, the cooling water inside the laser water circuit  freezes  and  expands.  The  resulting  force  can  rupture  pipelines  and  damage optical cables.

A single oversight may lead to costly repair fees and lengthy production downtime. Proactive protection is critical to keep your equipment running stably and safely through cold weather.

Below are key procedures and precautions for lasers operating in low-temperature environments:

01 Antifreeze Guidelines (Applicable when ambient temperature is below 0℃)

Why use antifreeze?

Antifreeze effectively lowers the freezing point of cooling water to prevent freezing and expansion, protecting water circuits and optical components.

Antifreeze selection

Recommended professional brand: Clariant Antifrogen N (pale yellow liquid).

Mixing ratio and corresponding freeze protection temperature

A 3:7 mixing ratio for Clariant antifreeze (30% antifreeze + 70% deionized water) delivers protection down to -20℃.

image.png

 

Proper antifreeze filling procedure

1. Power off all equipment (chiller, laser, etc.). Open the drain valve of the chiller to drain all water from the water tank, rinse the tank with clean water, then drain it again.

2. Remove, clean and reinstall the filter cartridge of the chiller and the filter at the laser inlet.

3. Pour the pre-mixed antifreeze and deionized water into a separate container and stir thoroughly before filling the chiller tank. (Do NOT pour them directly into the chiller; insufficient mixing will form flocculants that clog filters and cartridges.)

02 Important Notes

Antifreeze is not for permanent use. Once the cold season ends, flush the entire water circuit thoroughly and revert to deionized water or distilled water.

For long-term shutdowns (e.g., Spring Festival holiday), drain all cooling water and blow the water circuit dry with dry compressed air to avoid internal freezing.

Tap water and bottled purified water are prohibited, as they cause scale and microbial growth that clog pipelines.

03 Routine Maintenance for the Chilling System

· Cooling water specification: Only distilled water or deionized water is permitted.

· Replacement cycle: Replace water every 3 months to prevent water deterioration.

· Bacteria control: Add 5%–10% alcohol to suppress bacteria and algae growth.

04 Summary – Two Core Principles for Low-Temperature Maintenance

image.png

 

Prevention is the only way to avoid losses. Please implement protective measures promptly according to local climate and equipment operating conditions.

For further assistance, feel free to contact our service team.